Gas chromatograpgy - mass spectrometer

Organization: Teknologiakeskus KETEK Oy

Shimadzu GCMS-QP2010

Mikko Suomela

2003

2003

The high performance gas chromatograph with sensitive mass selective detection:

  • quadrupole mass spectrometer
  • electron (EI) and chemical ionization (CI)
  • spectrum library (NIST 2002)
  • maximum oven temperature 450 °C
  • two split and splitless injectors
  • automated sample injection unit

GC/MS is used in identification of unknown materials and quantitation of organic chemicals, analysis of chemicals in air, water, soil and polymers.

Pyrolysis-GC/MS is used in identification of unknown materials, polymers, additives and harmful chemicals and analysis of multi-layered polymers.

Thermal desorption-GC/MS is used identification and quantitation of volatile organic compound (VOCs) in air and solids when sample is extremely small.

Purge&Trap-GC/MS is used in quantitation of volatile organic coumpund (VOCs) in water and soil samples and polymeric materials when detection limits are small.

Headspace-GC/MS is used on identification (screening) of volatile compound of materials, polymers, quantitation of polymer additives and residual solvents.

There are following sample treatment equipment connected to GC/MS: pyrolysator, static headspace, purge&trap and thermal desorper.

PYROLYSATOR: PYROLA2000

  • heated platinum filament in inert atmosphere
  • maximum temperature + 1400 °C
  • extremely fast sample heating < 8ms
  • pyrolysis modes: single, sequential and fractionated
  • separated thermal desorption before pyrolysis
  • pyrotomy

 THERMAL DESORPTION: PERKINELMER TURBOMATRIX TD50

  • two-stage thermal desorption with (peltier) cold trap
  • maximum desorption temperature
  • on-column injection
  • automated sample treatment for 50 samples
  • high sample throughput
  • active and passive sampling for air media
  • sensitivity levels: % to ppt

 PURGE&TRAP: TEKMAR-DOHRMAN VELOCITY XPT AND SOLATEK 72

  • gas extraction with forward focusing chamber
  • maximum sample heating temperature +100 °C
  • automated sample treatment for 72 samples with solatek (heating, stirring, dilution and standard addition)
  • high sample troughoutput
  • high sensitivity: ppt-ppb

 STATIC HEADSPACE: TEKMAR- DOHRMANN 7050HT

  • maximum sample and system temperature + 300 °C
  • automated sample treatment for 50 sampleshigh sample throughput
  • sensitivity levels: ppm

Technology Centre KETEK Ltd

Kokkola